Alternative Names: |
CK2; CK-MB; Creatine Kinase,Muscle/Brain |
Catalogue No. |
3962ELK |
Size |
96T |
Reactivity |
Rat |
Range |
1.57-100 ng/mL |
Sensitivity |
0.67 ng/mL |
Assay Type |
Sandwich |
Sample Type |
serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids |
Assay Length |
3.5h |
Research Area |
Enzyme & Kinase; Cardiovascular biology; |
Test principle |
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Creatine Kinase MB Isoenzyme(CKMB). Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Creatine Kinase MB Isoenzyme(CKMB). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Creatine Kinase MB Isoenzyme(CKMB), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Creatine Kinase MB Isoenzyme(CKMB) in the samples is then determined by comparing the OD of the samples to the standard curve. |
Standard Curve |
Concentration (ng/mL) |
OD |
Corrected OD |
100.00 |
2.037 |
1.952 |
50.00 |
1.315 |
1.230 |
25.00 |
0.976 |
0.891 |
12.50 |
0.782 |
0.697 |
6.25 |
0.457 |
0.372 |
3.13 |
0.354 |
0.269 |
1.57 |
0.161 |
0.076 |
0.00 |
0.085 |
0.000 |
|
Precision |
Intra-assay Precision (Precision within an assay):CV%<8%
Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.
Inter-assay Precision (Precision between assays):CV%<10%
Three samples of known concentration were tested in forty separate assays to assess inter-assay precision. |
Recovery |
Matrices listed below were spiked with certain level of recombinant CKMB and the recovery rates were calculated by comparing the measured value to the expected amount of CKMB in samples.
Matrix |
Recovery range |
Average |
serum(n=5) |
85-97% |
91% |
EDTA plasma(n=5) |
82-94% |
88% |
Heparin plasma(n=5) |
82-94% |
88% |
|
Linearity |
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of CKMB and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix |
1:2 |
1:4 |
1:8 |
1:16 |
serum(n=5) |
92-105% |
92-101% |
80-94% |
86-101% |
EDTA plasma(n=5) |
85-94% |
87-99% |
85-101% |
79-90% |
Heparin plasma(n=5) |
92-105% |
82-92% |
86-94% |
81-95% |
|
Note |
For Research Use Only |
Reviews
There are no reviews yet.