Nicotinamide Adenine Dinucleotide (NAD) ELISA Kit

Catalogue No BSELK-044U
Size 96 T
Price $ 900
Range 123.5-10,000ng/mL
Sensitivity 49.3ng/mL
Contact Us
SKU: BSELK-044U Categories: ,
Product Name Nicotinamide Adenine Dinucleotide (NAD)
Species General
Test Method Competitive Inhibition
Sample Type Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
Assay Length 2h

Specificity

This assay has high sensitivity and excellent specificity for detection of Nicotinamide Adenine Dinucleotide (NAD). No significant cross-reactivity or interference between Nicotinamide Adenine Dinucleotide (NAD) and analogues was observed.

Recovery

Matrices listed below were spiked with certain level of Nicotinamide Adenine Dinucleotide (NAD) and the recovery rates were calculated by comparing the measured value to the expected amount of Nicotinamide Adenine Dinucleotide (NAD) in samples.

Matrix Recovery Range(%) Average Recovery(%)
serum(n=5) 96-105 101
EDTA plasma(n=5) 87-102 96
heparin plasma(n=5) 85-97 93

Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Nicotinamide Adenine Dinucleotide (NAD) were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Nicotinamide Adenine Dinucleotide (NAD) were tested on 3 different plates, 8 replicates in each plate.

CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%

Linearity

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Nicotinamide Adenine Dinucleotide (NAD) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample 1:2 1:4 1:8 1:16
serum(n=5) 94-102% 79-90% 98-105% 91-99%
EDTA plasma(n=5) 89-104% 92-101% 94-102% 89-96%
heparin plasma(n=5) 87-96% 82-95% 89-103% 91-105%

Stability

The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

 

 

 