Rat Bcl2 ELISA Kit

$450.00

Catalogue No. 5251ELK
Size 96T
Alternative Names B-Cell CLL/Lymphoma 2
Reactivity Rat
Range 78.13-5000 pg/mL
Sensitivity 28 pg/mL
SKU: N/A Categories: ,

Description

Product Name Rat Bcl2(B-Cell Leukemia/Lymphoma 2) ELISA Kit
Catalogue No. 7760ELK
Alternative Names: B-Cell CLL/Lymphoma 2
Assay Type Sandwich
Sensitivity 28 pg/mL
Range 78.13-5000 pg/mL
Sample Type serum, plasma, tissue homogenates and other biological fluids
Assay Length 3.5h
Research Area Signal transduction;Apoptosis;
Test principle The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to B-Cell Leukemia/Lymphoma 2(Bcl2). Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to B-Cell Leukemia/Lymphoma 2(Bcl2). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain B-Cell Leukemia/Lymphoma 2(Bcl2), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of B-Cell Leukemia/Lymphoma 2(Bcl2) in the samples is then determined by comparing the OD of the samples to the standard curve.
Standard Curve
Concentration (ng/mL) OD Corrected OD
5000.00 2.096 2.020
2500.00 1.587 1.511
1250.00 1.142 1.066
625.00 0.855 0.779
312.50 0.576 0.500
156.25 0.297 0.221
78.13 0.134 0.058
0.00 0.076 0.000

Precision Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

Recovery Matrices listed below were spiked with certain level of recombinant Bcl2 and the recovery rates were calculated by comparing the measured value to the expected amount of Bcl2 in samples.

Matrix Recovery range Average
serum(n=5) 82-94% 88%
EDTA plasma(n=5) 82-98% 90%
Heparin plasma(n=5) 80-97% 88%
Linearity The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Bcl2 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.

Matrix 1:2 1:4 1:8 1:16
serum(n=5) 90-99% 95-106% 87-101% 82-97%
EDTA plasma(n=5) 80-92% 86-102% 87-103% 85-101%
Heparin plasma(n=5) 85-94% 90-99% 95-102% 82-90%
Note For Research Use Only