Product Name |
Human IL-13(Interleukin 13) ELISA Kit |
Catalogue No. |
EH3266 |
Synonyms |
IL-13 ELISA Kit, Interleukin 13 ELISA Kit, BHR1interleukin-13 ELISA Kit |
Detection Method |
Sandwich ELISA, Double Antibody |
Application |
IL-13 ELISA Kit allows for the in vitro quantitative determination of IL-13 concentrations in serum, plasma, tissue homogenates and other biological fluids. |
Size |
96T |
Range |
15.625-1000pg/ml |
Sensitivity |
< 9.375pg/ml |
Species |
Human |
Standard Curve |
 |
Storage |
2-8 ℃ for 6 months |
Recovery |
Matrices listed below were spiked with certain level of IL-13 and the recovery rates were calculated by comparing the measured value to the expected amount of IL-13 in samples.
Matrix |
Recovery range(%) |
Average(%) |
serum(n=5) |
93-105 |
99 |
EDTA plasma(n=5) |
85-105 |
92 |
heparin plasma(n=5) |
85-100 |
96 |
|
Linearity |
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of IL-13 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample |
1:2 |
1:4 |
1:8 |
serum(n=5) |
85-105% |
91-98% |
91-102% |
EDTA plasma(n=5) |
84-101% |
82-99% |
88-100% |
heparin plasma(n=5) |
94-98% |
81-97% |
81-100% |
|
CV(%) |
Intra-Assay: CV<8%
Inter-Assay: CV<10% |
Note |
For Research Use Only |
Reviews